| Minimum Order Quantity: | 100 |
|---|---|
| Packaging Details: | Original packing |
| Delivery Time: | 1-12 weeks |
| Payment Terms: | T/T |
| Certification: | ISO9001 | Rated Output: | 0.333V(AC) Or 0-500mA |
|---|---|---|---|
| Rated Frequency: | 50-60 Hz | Working Temp.: | -30℃ ~ +60℃ |
| Insulation Resistance: | >500MΩ/500VDC | Storage Temp.: | -30℃ ~ +70℃ |
| Color: | Black / White | Coil Structure: | Toroidal |
| Highlight: | 0.333VAC Hall Current Transducer,Toroidal Coil Hall Current Transducer,Hall Current Sensor EN50155 |
||
product manual
NACL-500R1-S5/SP2 magnetic balance Hall current sensor is suitable for accurate measurement of AC, DC, and pulse current isolation. The primary side and the secondary side are completely insulated during measurement.
| product advantages | Applications | Reference standard |
| High precision | AC Inverter AC | GB/T 25119-2010 EN50178 EN50155 |
| Good linearity | Private server motor drive | |
| Low temperature drift | Battery powered | |
| Broadband | Converter/Inverter | |
| Quick response | UPS/SVG |
| Main electrical parameters (@±IPN, TA = 25℃) | |
| Rated measuring current IPN | 500A |
| Measuring range IPM | ±800A |
| Power supply voltage VC | DC±(15~18)×(1±5%)V |
| Current consumption IC (@±24V) | ≤±25mA+ISN |
| Rated measurement output ISN | 100mA |
| Turns ratio | 1:5000 |
| Load resistance RM | @±15V, ±500A: 0Ω~40Ω @±15V, ±800A: 0Ω~5Ω @±18V, ±500A: 0Ω~60Ω @±18V, ±800A: 0Ω~15Ω |
| Accuracy-dynamic parameters | |
| Basic error δi(@IPN,TA=25℃) | ≤±0.4% |
| Linearity δL(@IPN,TA=25℃) | ≤±0.1% |
| Zero output current IO (@IP=0, TA = 25℃) | ≤±0.13mA |
| Zero temperature drift IOT | ≤±0.64mA (@-25℃~+70℃) |
| Response time TR (90% of IPN&di/dt> 50 A/µS) |
≤1µS |
| General data | |
| Working temperature Ta | -25~+70℃ |
| Storage temperature Ts | -40~+85℃ |
| Weight m | ≤400g |
| Insulation withstand voltage | |
| Withstand voltage | 6kV |