Minimum Order Quantity: | 100 |
---|---|
Packaging Details: | Original packing |
Delivery Time: | 1-12 weeks |
Payment Terms: | T/T |
Maximum Range: | 700A~900A | Operating Temperature: | -40 - 125 |
---|---|---|---|
Output Voltage (linear): | Vout=(Uc/5)·(V0+G·Ip) | Sensitivity: | G=2000/IP |
Zero Output: | 2.5 | Current Consumption: | 39 |
Load Resistance: | 10 | Bandwidth: | 40 |
High Light: | 700A AC Current Transducer,40kHz AC Current Transducer |
product manual
NACA XXXQ2-S5/SP1VA series triple current sensor is suitable for accurate measurement of AC, DC and pulse current isolation. The primary side and the secondary side are completely insulated during measurement.
Performance requirements | ||||||
parameter name | symbol | unit | parameter | condition | ||
Minimum | Typical value | Max | ||||
Electrical parameters | ||||||
Maximum range | IP | A | 700A~900A | For more details, please contact CRRC | ||
voltage | UC | V | 4.75 | 5 | 5.25 | |
Operating temperature | TA | °C | -40 | 125 | ||
Output voltage (linear) | Vout | V | Vout=(Uc/5)·(V0+G·Ip) | |||
Sensitivity | G | mV/A | G=2000/IP | @UC=5V | ||
Zero output | VO | V | 2.5 | |||
Current consumption | IC | mA | 39 | 45 | @ UC=5V,No load on Vout | |
Load Resistance | RL | KΩ | 4.7 | 10 | ||
Load capacitance | CL | nF | 5 | |||
Output internal resistance | ROUT | Ω | 2 | 4 | 8 | DC |
Performance parameter | ||||||
Sensitivity error | εG | % | ±1 | @TA=25℃,@UC=5V | ||
±2 | @-40℃<TA<125℃,@UC=5V | |||||
Electrical zero offset | FLY | mV | ±4 | |||
Magnetic zero offset | FROM | mV | ±3 | |||
Zero output error | X0 | % | ±0.5 | @TA=25℃,@UC=5V | ||
±0.75 | @-40℃<TA<125℃,@UC=5V | |||||
Proportional error | εR | % | ±0.5 | |||
Linearity error | εL | % | ±0.5 | of full range | ||
Response time | tr | μs | 2 | |||
bandwidth | BW | kHz | 40 | @ -3dB | ||
Phase difference | ∆φ | ° | -4 | @DC to 1kHz |
Procurement information
1. Products can be customized according to your needs. You are welcome to provide physical samples or detailed process drawings to design, produce and process.
2. If there is no special requirement, our company will assign logistics distribution and deliver the goods to customer factory
3. Payment method: delivery after payment, which can be negotiated according to the specific order quantity.
4. The response time of the number of customers should not exceed 8 working hours.
5. Emergency on-site service time shall not exceed 24 hours.
6. Provide emergency support for customer's urgent shortage of spare parts.
Contact Person: Miss. Elaine
Tel: +86 18150151931
Fax: 86-592-2611505