| Minimum Order Quantity: | 100 |
|---|---|
| Packaging Details: | Original packing |
| Delivery Time: | 1-12 weeks |
| Payment Terms: | T/T |
| Rated Voltage (A): | 1500V | Product Number: | NV100-1500V |
|---|---|---|---|
| Measuring Range: | 0~±2250V | Working Principle: | Magnetic Balance |
| Power Supply Voltage (V): | ±15 × (1±5%)V | Rated Measurement Output: | 40mA |
| Basic Error: | ≦±1 % | Linearity Error: | ≦0.1% |
| Highlight: | 1500VA Voltage Transducers,40mA Magnetic Balance Voltage Transducers |
||
| NV100-1500V rail voltage sensor model specifications and technical parameters | |
| Rated voltage (A) | 1500V |
| Product number | NV100-1500V |
| Measuring range | 0~±2250V |
| working principle | Magnetic balance |
| Power supply voltage (V) | ± 15 × (1 ± 5%) V |
| Rated measurement output | 40mA |
| Basic error | ≦±1 % |
| Linearity error | ≦0.1% |
| Zero output error (+25 ℃ ) | ≦ ± 0.2mA |
| Response time | ≦120us |
| Withstand voltage | 6kV/50Hz/2min |
| Operating temperature | -40℃-+85℃ |
Dimensions of NV100-1500V rail voltage sensor
![]()
Contact Person: Miss. Elaine
Tel: +86 18150151931
Fax: 86-592-2611505